e ISSN- 2249-7668

Print ISSN- 2249-7676

ISSN

2249-7676

e ISSN

2249-7668

Publisher

pharmacology and toxicology

EVALUATION OF A NOVEL HYPOGLYCAEMIA MANAGEMENT PROTOCOL IN NEONATES: A PILOT RANDOMIZED CONTROLLED TRIAL
Author / Afflication
Dr. Jyoti

Assistant Professor, Department of Pediatrics, Lord Buddha Koshi Medical College, Saharsa, Bihar, India
Keywords
Neonates, Hypoglycemia, Glycemic Control ,Gastric Emptying Rate, Intravenous Fluids, Pilot Rct ,
Abstract

The purpose of the study was to compare the neonates with hypoglycemia should be treated according to the standard protocol; a new protocol is evaluated for safety. A pilot RCT with an open label. We included neonates who required intravenous fluids due to hypoglycemia during their stay in the NICU. An intervention group of 114 eligible neonates (glycemic control increased by 1.5%) and a standard protocol group (gastric emptying rate increased by 2 mg/kg/min) were randomly assigned. The primary aim of the study was to determine the Following enrollment in the study, the percentage of infants who developed hypoglycemia and hyperglycemia. The initial GIR (6 ± 0?mg/kg/min versus 4.8 ± 1.4?mg/kg/min, P < 0.001), the mean maximum GIR (6.7 ± 1.6?mg/kg/min versus 5.6 ± 2?mg/kg/min, P = 0.03), the maximum concentration of glucose infused (13.8 ± 2.9% versus 10.9 ± 1.9%, P < 0.001), and the total amount of glucose infused in the intervention group, were significantly lower. Compared to the conventional protocol group where there were only five infants with hyperglycemia There was a significant difference between groups (n = 20, 39% versus n = 10, 16%, P = 0.07) in the mean maximum blood sugar levels (129x57 mg/dL versus 87x30 mg/dL, P = 0.001). When the highest and lowest recorded sugar concentrations were compared in the standard protocol group (median 93 mg/dL, IQR 52 to 147 mg/dL versus median 50 mg/dL, IQR 38 to 62.5 mg/dL, P = 0.03), significant differences were observed. Hypoglycemia in neonates can be managed effectively with a new and innovative algorithm, but this needs to be tested further before it is practiced routinely

Volume / Issue / Year

11 , 2 , 2021

Starting Page No / Endling Page No

62 - 66